zur deutschen Sprache wechseln  englisch language loaded
Interlock Medizintechnik GmbH
Zum Windpark 1
D-23738 Lensahn

Telefon: +49(0) 4363 905900
Telefax: +49(0) 4363 90590590
Internet:
http://www.interlockmed.de

E-Mail: info@interlockmed.de
search
Online-catalogue



Bitte warten... Katalogseite wird geladen.

There are items on your sample-request/order form

Quality assurance
Test-equipment according to DIN 58298
08500 To test the functional capability of medical
instruments (according to DIN 58298).
The test-equipment includes test material for
the following medical instruments:
  • bone cutting forceps and rongeurs, bone punches
  • cutting conchotomes
  • scalpels and knives
  • non-cutting conchotomes
  • surgical scissors
  • forceps
  • needle holders
  • atraumata forceps
  • chisels, raspatories, bone curettes and gouges
1 set

Contents:
  • for bone cutting forceps and rongeurs, bone punches: cardboard 250 g/m2 (50 sheets)
  • for scalpels and knives and for cutting conchotomes: synthetic film 0.05 - 0.1 mm (100 sheets) cylinder made of synthetic material (1 pc.)
  • for non-cutting conchotomes: synthetic film 0.3 mm (50 pcs.)
  • for surgical scissors: control material 1.5 m (2 plies)
  • for forceps: plates made of synthetic material 1.0 / 1.5 / 2.0 mm (5 pcs./size), 2.5 / 3.0 / 4.0 mm (3 pcs./size)
  • for needle holders: synthetic thread USP 4/0  25 m (1 reel), synthetic thread USP 6/0  25 m (1 reel), wire 0.4 / 0.6 / 0.8 / 1.0 mm (10 pcs./size)
  • for atraumata forceps: paper 30 g/m2 (1 pad)
  • for chisels, raspatories, bone curetts and gouges: plastic round profiles (3 pcs.)
  • magnifying glass with 5 x zoom, with light, incl. 2 x 1,5V AAA batteries (1 pc.)
  • spring scale with Newton graduation 0-25 N (1 pc.)
  • additional test-equipment (not according to DIN 58298): for rigid endoscopes: magnifying glass to test the inner lenses (1 pc.)



Refill packs
08501 - for bone cutting forceps and rongeurs, bone punches
- for scalpels and knives and for cutting conchotomes
- for non-cutting conchotomes
- for atraumata forceps
 
1 pack



 
08502 - for surgical scissors1 pack



 
08503 - for forceps
- for chisels, raspatories, bone curettes and gouges
 
1 pack



 
08504 - refill pack for needle holder1 pack



Spring scale
09987 with Newton graduation 0-25 N1 pc.



SEAL PROOF
To test rotary sealers.
Deviations (sealing temperature, sealing
pressure) are visible on the indicator.
1. Put the test sheet into your flat pouch.
2. Pass it through the sealer once.

08011 173 mm x 91 mm
for pouches made of paper / film

250 pcs.
08022 173 mm x 91 mm
for pouches made of paper / film

50 pcs.
08017 172 mm x 90 mm
for pouches made of tyvek
100 pcs.



STERIKING Seal Control
Sterilization packages have to be
sealed to prevent the ingress of
micro-organisms and the sealing
process needs to be validated accordingly.
Under the new ISO standard 11607-2:2006
users and processors are responsible to
carry out a process validation program
demonstrating the efficacy and reproduceability
of all sterilization and packaging processes.
The Steriking® Seal Control sheet SC250
enables users to validate sealers and seal quality
reliably and rapidly.
08021 size:
205 x 150 mm
250 pcs.



Magnifying lamp with 16 W neon ring
09980 table lamp with adjustable arm (120 cm)
material: steel and plastic
120 mm real glass lens with 5 dioptres
2.25 x zoom
16 W neon ring (1 x included)
on/off switch on lamp
table clip with screw fitting (clamp area: 6 cm)
hinged cover to protect the lens
easy to clean
internal springs
operates on 230 V
colour: white
light colour: cold white
1 pc.
09981 replacement neon ring1 pc.



LED-Magnifying lamp
09979 table lamp with adjustable arm (126 cm)
material: rugged plastic
125 mm lens with 3 dioptres
1.75 x zoom
48 LED´s
on/off switch on lamp
real glass lens
table clip with screw fitting (clamp area: 6 cm)
hinged cover to protect the lens
easy to clean
internal springs
operates on 230 V
colour: white
1 pc.



Wall bracket for magnifying lamps
09974 suitable for REF 09979 and 099801 pc.



Alternative lens
09976 applicable for REF 09979 and 09980
diameter: 127 mm
with 5 dioptres
2.25 x zoom
1 pc.



Lamp stand for magnifying lamp
09982 colour: white
height: 1 m
base with 4 reels
1 pc.



Magnifying lamps with 12 W fluorescent ring
09983 table lamp with flexible swanneck (29 cm)
material: rugged plastic
100 mm lens with 3 dioptres
1.75 x zoom
12 W fluorescent ring (1 x included)
on/off switch integrated into base
real glass lens
hinged cover to protect the lens
easy to clean
operates on 230 V
colour: white
light colour: cold white

1 pc.
09984 replacement fluorescent ring1 pc.



09978 material: rugged plastic
90 mm lens with 3 and 12 dioptres
12 W fluorescent ring (1 x included)
on/off switch integrated into base
hinged cover to protect the lens
easy to clean
operates on 230 V
colour: white
light colour: cold white

1 pc.
09988 replacement fluorescent ring1 pc.



Magnifying lamp with clamp
09989 magnifying table lamp with clamp, white
with flexible swanneck (29 cm)
with 12 W fluorescent ring, 90 mm lens,
3 dioptres, 1.75 x zoom,
operates on 230 V
1 pc.



Head magnifying glass
09985 adjustable dioptre: 1.8/ 2.3/ 3.7/ 4.8
with dual light
power supply: 4 x 1.5 V AAA batteries (incl.)
1 pc.



Magnifying glass
08514 2.5 x zoom
with LED light
made of aluminium
incl. 2 x 1.5 V AA batteries
incl. case for safekeeping
1 pc.



Magnifier
08509 magnifier for rigid endoscopes
10 x zoom
1 pc.



Hand microscope
09990 digital hand microscope with computer
connection (USB) with LED`s
power supply via USB
with tripod base
incl. software for screen output
min. requirement: Windows XP SP2
resolution: 4.9 megapixels
magnification: 1.5 times to 200 times

1 pc.
09991 angle mount for REF 09990, made of steel,
height adjustable
1 pc.



09998 digital hand microscope with computer connection (USB) with LED`s
power supply via USB
incl. software for screen output
min. requirement: Windows XP
with autofocus
resolution: 2.0 megapixels
magnification: 15~65 times, 225 times

1 pc.
09999 angle mount for REF 09998
height adjustable
2-axis movable platform with stage clips
adjustable LED light source (power by battery or USB port)
1 pc.



Digital caliper
09800 silver coloured digital caliper
6-digit jumbo LCD display
measuring range 0-150 mm
resolution 0.1 mm
metric / inch change-over
auto power-off function
supply with two 1.55 V button cells and one
stable box
1 pc.



Digital timer
26045 digital timer
with memory function
countdown and stopwatch function
time range 00 M 01 S - 99 M 59 S
batteries are not included in this package
1 pc.



Josafe CCI easy
AnwendungsbeispieleAnwendungsbeispiele
AnwendungsbeispieleAnwendungsbeispiele
AnwendungsbeispieleAnwendungsbeispiele
AnwendungsbeispieleAnwendungsbeispiele
50052 cleaning indicators for the routine monitoring
of washer-disinfectors according to ISO 15883
18 pcs.



Indicator "Wash-Check"
AnwendungsbeispieleAnwendungsbeispiele
AnwendungsbeispieleAnwendungsbeispiele
AnwendungsbeispieleAnwendungsbeispiele
08554 the test soil simulates human blood and tissue residues,
for validation of cleaning and disinfection process
in washer disinfector
10 pcs.



Quick protein test
01420 Miele quick protein test
for surgical instruments
set for 48 determinations
1 set



Pro-Check indicator
08005 for control of cleaning and disinfection process
of washer-disinfector and for control of surface
cleaning procedure

50 swabs with 2 indicators
(double ended
swabs) / box
1 box



pH-Test
08018 pH test strip
pH 1 - 14
50 pcs.



pH-Tester 0.2 pH
08505 - range 0.00 - 14.00 pH
- resolution 0.1 pH
- accuracy +/- 0.1 pH
1 pc.



Storage solution for electrodes
(pH-Tester REF 08505)
08525 230 ml1 bottle
08526 500 ml1 bottle



Buffer solution pH 7 and pH 10
to calibrate the pH-Tester REF 08505
08507 5 pouches pH 7 / 20 ml
5 pouches pH 10 / 20 ml
1 package



Economical EC Tester 10-19 DiST3
08506
  • range 0 - 1990 μS/cm
  • resolution 10 μS/cm
  • accuracy (20 °C) +/- 2% of the measuring range
1 pc.



Conductivity calibration solution 1413 μS/cm
to calibrate the Economical EC tester REF 08506
08508 calibration solution
230 ml
1 bottle






Routine monitoring for steam sterilization

Interlock Bowie & Dick single use test
04012 Interlock Bowie & Dick single use test
according to EN ISO 11140-4 class 2
for steam sterilizer with pulsed flow
vacuum process
134 °C / 3.5 min
1 package



Bowie & Dick test sheet from propper
04006 Bowie & Dick test sheet from propper
according to EN 867 part 3
for steam sterilizer with pulsed flow
vacuum process
134 °C / 3.5 min
size: 295 x 210 mm
50 sheets



Bowie & Dick multiple test pack
for sterilizer with pulsed flow vacuum process
DIN A4
220 x 295 mm
without indicator
for 20 applications
04200 for TOLZIN clamping frame1 package
04202 for HAWO clamping frame1 package



 
04201 DIN A6 Bowie & Dick
106 x 148 mm
for TOLZIN clamping frame
without indicator
for 20 applications
1 package



Routine monitoring
steam penetration test according to DIN EN ISO 11140
1001013 DIN A6 Bowie & Dick-Simtest test sheet
pack: 50 indicator sheets/50 laminated sheets
1 package



Batch control
hot air indicator class 4 / thermotest H
08001 Indicator for hot air sterilization.
The strips undergo a complete change of colour
from white to brown depending on the time and
temperature. A colour sample for an exposure time
of 30 min. at 180 °C is enclosed in each package
with the product information sheet.
size: 10 x 60 mm
200 strips / box
1 box



Batch control
hot air indicator class 4 / thermocontrol
08002 Indicator for hot air sterilization, self-adhesive,
with punch holes and perforation. To facilitate
documentation, after sterilization the individual
strips can be stuck onto the five documentation
sheets supplied.
A test strip for an exposure time of 30 min. at
180 °C makes it easier to evaluate the indicator.
size: 9 x 48 mm
120 strips / box
1 box



Batch control
steam control indicator - class 5
08003 Steam indicator for self-checking.
Sterilization with saturated steam and at
temperatures between 121 °C and 134 °C. Colour
change from ochre-brown through grey to black.
Size of individual indicator: 6 x 74 mm,
single self-adhesive.
Test strips supplied make it easier to evaluate
the indicator after sterilization.
200 strips / box, with test tube
1 box



Batch control
FO indicator - class 4
08006 Indicator for steam-formaldehyde sterilization;
colour change depends on formaldehyde
concentration, exposure time and operating
temperature.
Size of individual indicator: 6 x 74 mm,
single self-adhesive.
Test strips supplied make it easier to evaluate
the indicator after sterilization.
Colour change from beige to deep violet.
200 strips / box, with test tube
1 box



Three-Phase Sequential Indicator
steam indicator - class 5
The blue indicator changes to black when exposed to steam but this change does not ensure the sterilization process' efficiency (UNSAFE).
The pink indicator changes to black to obtain the stated values of the critical variables for class 5 indicators.
These values are obtained when the sterilizer is able to heat the steam at 134 ºC for 3.5 minutes or 15 minutes at 121 ºC. This situation is named OK.
Longer exposure times or higher temperatures can be determined when the green indicator changes to dark brown up to black.
This situation is named OPTIMUM.
08026 mode:
134 °C / 3.5 min.
121 °C / 15 min.

250 pcs. / box
1 box



Three-Phase Sequential Indicator
steam indicator - class 6
The blue indicator changes to black when exposed to steam but this change does not ensure the sterilization process' efficiency (UNSAFE).
The green indicator changes to black when the sterilization process has achieved
134 ºC for 5.3 minutes. This situation is named OK.
Longer exposure times or higher temperatures can be determined when the yellow indicator changes to dark brown up to black.
This situation is named OPTIMUM.
08027 mode:
134 °C / 5.3 min.

250 pcs. / box
1 box



Steam-control-indicator - class 6
08016 The emulating indicators react to all critical
parameters. Parameters for the steam
sterilization: Time, temperature and condensate
(saturated steam).
mode:
134 °C / 3.5 min.
121 °C / 15 min.

250 pcs. / box
1 box



Des Check for moist heat processes
Cycle verification indicators for use
in moist heat processes.

The Des Check range provides an
accurate, convenient method of routine
control for moist heat processes. When
distributed throughout the load, the
indicators provide visual confirmation of
conditions achieved at point of
placement. The vivid colour change from
yellow to blue gives clear evidence of the
conditions attained, thus allowing a quick
and easy assessment of the success of
the process.
Designed using advanced polymer
technology to withstand conditions
present during moist heat processes.

Des Check technology can be applied to
different time and temperature
combinations. Please contact us to
discuss your individual cycle
requirements.

Store at or below 0 °C.

50000 order code STERIS / BROWNE 2470AB
93 °C / 10 min.
100 indicators / box
according to
ISO 11140-1 class 6

1 box
50001 order code STERIS / BROWNE 2471AB
90 °C / 5 min.
100 indicators / box
according to
ISO 11140-1 class 6


1 box



Batch control
Soil test for washer-disinfector
Inefficient cleaning can put disinfection
and sterilization procedures at risk. A
poorly functioning washer-disinfector can
leave behind microscopic debris that can
severely compromise both the
disinfection and sterilization process.
One of the best and easiest ways to
check whether instruments are being
cleaned effectively is to present the
cleaning equipment with a physical
challenge such as the cleaning efficacy
tests described in BS2745(9),
ISO/TS 15883-5:2005(10) and UK
Guidance Document HTM2030(11).

The Browne Washer-Disinfector Test Soil
is designed to simulate the soiling that
naturally occurs during theatre use and
performs in an equivalent manner to the
Edinburgh soil.
The Browne Soil Test is supplied in
powder form as individual test pots.
One pot, one test.
Simply add water to the fill line, replace
the cap, shake vigorously and apply to
the test load with the brush provided.
Following a 30-minute** drying period at
room temperature, the test load should
be cleaned using normal procedures and
then inspected for residual soil. Detailed
instructions for use included in each box.

The bright red colour of the Browne Test
Soil allows easy identification of areas
that have not been properly cleaned,
providing a visual analysis of equipment
efficiency.

Non-toxic; contains no blood products.

** Drying time should not exceed 2 hours.
50002 order code STERIS / BROWNE 2304AB
10 ready to use tests / box
1 box



Batch control
STF Load Check for washer-disinfectors
The STF Load Check indicator and holder
are intended for use inside each basket
or tray to verify the cleaning efficacy of a
surgical instrument washer-disinfector machine.

The dried test soil formula, printed on
both sides of the indicator, contains two
sources of protein, lipids and
polysaccharides and is formulated to
mimic the cleaning efficacy soil tests for
surgical instruments described in
BS2745(9), ISO/TS 15883-5:2005(10) and
UK Guidance Document HTM2030(11).

Simply place an STF Load Check indicator
in the holder, and place the device
(indicator and holder) in the tray or
basket. After running one complete cycle,
remove the STF Load Check indicator
from the holder and examine for evidence
of residual soil.
Complete removal of the dried ‘test soil’
pattern from the plastic substrate
provides a qualitative assessment of the
washer-disinfector cleaning performance.

50003 order code STERIS / BROWNE 2315AB
Load Check indicator
100 indicators / box


1 box
50004 order code STERIS / BROWNE 2316AB
Load Check holder
1 pc.



Batch control
TST Bowie & Dick single use test pack / for steam sterilization
for small sterilizers type B and large sterilizers
A successful test confirms that steam
penetration into a test pack is rapid and
even and, by implication, that air and
other non-condensable gases have been
effectively removed. The chemical
indicator sheet at the centre of the pack
shows a defined colour change from
yellow to dark blue / purple when
exposed to a specific combination of
time, temperature and steam. When
there is no air or other non-condensable
gases in the chamber, steam will
penetrate the pack rapidly and
completely and the indicator will show a
uniform colour change. When air or other
non-condensable gases are present they
will collect towards the centre of the pack
as an air / gas pocket which will impair
contact between the steam and the
indicator sheet. The temperature or
moisture level (or both) will be lower in
the region of the air / gas pocket and will
result in a non-uniform colour change of
the indicator; distinct yellow markings
will be evident on the sheet.

50005 Matachana M20 – B
134 °C - 137 °C up to 3.5 min.
order code STERIS / BROWNE 2352 AB
20 test packs / box
according to EN 867 – 5
1 box



TST Helix control-strip for steam sterilization
The Browne TST Helix is a Hollow Load
Process Challenge Device (PCD) as
defined in EN 867-5 and has been
developed and validated for testing of small
Type B steam sterilizers only.
Use in any other sterilizer or with any
other type of indicator, may give
dangerously misleading results.
A successful test confirms steam
penetration through the helix and
confirms by implication that air and other
non-condensable gases have been
removed.

50010 order code STERIS / BROWNE 3780AB
1 TST PCD and 250 indicator strips / set
1 set



Batch control
TST Load Check for steam sterilization
TST Load Check for batch control

50006 order code STERIS / BROWNE 3783AB
batch control 3.5 min. / 134 °C
1 PCD and 400 indicator strips / set


1 set
50007 order code STERIS / BROWNE 3777AB
batch control 4.0 min. / 134 °C
or 12 min. / 121 °C
1 PCD and 400 indicator strips / set


1 set
50008 order code STERIS / BROWNE 3778AB
batch control 5.3 min. / 134 °C
or 15 min. / 121 °C
1 PCD and 400 indicator strips / set


1 set
50009 order code STERIS / BROWNE 3779AB
batch control 7.0 min. / 134 °C
or 20 min. / 121 °C
1 PCD and 400 indicator strips / set
1 set



Formaldehyd Load Check
Formaldehyd Load Check for
batch control

50014 order code STERIS / BROWNE 2445AAB
1 PCD and 200 indicator strips / set
1 set



Batch control
TST control indicator for steam sterilization
Browne Cycle Verification (Emulating)
Indicators are the third of three types
of indicators available for ‘in-pack’
monitoring.

according to
ISO 11140-1 Class 6

50051 order code STERIS / BROWNE 2340AB
batch control 3.5 min. / 134 °C
100 pcs. / box

1 box
50011 order code STERIS / BROWNE 2342AB
batch control 5.3 min. / 134 °C
or 15 min. / 121 °C
100 pcs. / box


1 box
50025 order code STERIS / BROWNE 3726AB
batch control 5.3 min. / 134 °C
or 15 min. / 121 °C
single self-adhesive
100 pcs. / box


1 box
50012 order code STERIS / BROWNE 3760AB
batch control 7.0 min. / 134 °C
or 20 min. / 121 °C
200 pcs. / box


1 box
50024 order code STERIS / BROWNE 3725AB
batch control 7.0 min. / 134 °C
or 20 min. / 121 °C
self-adhesive
200 pcs. / box


1 box
50013 order code STERIS / BROWNE 3706AB
batch control 18 min. / 134 °C prion
200 pcs. / box
1 box



Batch control
Ethylene oxide integrating indicator
Ethylene Oxide Integrators should be
placed inside each pack.
The control indicator turns from red to
green when adequate sterilizing
conditions have been reached, giving the
end-user assurance that adequate
sterilizing conditions occurred at point of
placement.

Ethylene Oxide Integrators will show a
fail if the relative humidity level, gas
concentration, temperature or duration of
exposure fall outside of the
specified limits.

900 mg Concentration (mg per litre)
Temperature: 37 ºC - 55 ºC
Time: 20 - 55 minutes
Humidity: 40–60 %

600 mg Concentration (mg per litre)
Temperature: 37 ºC - 55 ºC
Time: 35 - 70 minutes
Humidity: 40–60 %

It is recommended that Browne Ethylene
Oxide Process Detector (Order Code
2421) Spots are placed on the outside of
each pack to allow processed and
unprocessed items to be identified at a
glance. Note however that the spots are
not calibrated for use as an ‘in-pack’
control indicator.

according to
ISO 11140-1 class 5

50017 Ethylene oxide integrating indicator
order code STERIS / BROWNE 2420AB
100 indicator cards / box
1 box



Batch control
Formaldehyde control – indicator
Formaldehyde Control Indicators should
be used inside each pack to show that
Low Temperature Steam and
Formaldehyde gas (LTSF) have penetrated
the pack in a sufficient quantity and for
the correct length of time for sterilization
to occur.

The control indicator turns from blue to a
complete green when adequate sterilizing
conditions have been reached.

It is recommended that Browne
Formaldehyde Process Detector (Order
Code 2402) Spots are placed on the
outside of each pack to allow processed
and unprocessed items to be identified at
a glance.

Note that the spots are not
calibrated to be used as an ‘in-pack’
control indicator.

according to
ISO 11140-1 class 4

50015 order code STERIS / BROWNE 2401AB
100 indicator strips / box
1 box



Detector spots for Formaldehyde and Ethylene oxide sterilization
The self-adhesive spots should be placed
on the outside of every pack being
sterilized. The spots change colour after
passing through the process allowing
differentiation between processed and
unprocessed loads.

Note:
The spots do not act as a control and are
not intended as a guide to the efficacy of
the process.

according to
ISO 11140-1 class 1

50016 detector spots for formaldehyde
order code STERIS / BROWNE 2402AB
250 spots / box

1 box
50018 detector spots ethylene oxide
order code STERIS / BROWNE 2421AB
1000 spots / box
1 box



Batch control
Sterilization control tubes
for the fluid, steam and heat sterilization
50019 type 1 black spot
order code STERIS / BROWNE 7301AB
fluid sterilization 121 ºC / 15 min.
100 pcs. / box


1 box
50020 type 2 yellow spot
order code STERIS / BROWNE 7302AB
steam sterilization* 134 ºC / 3 min.
100 pcs. / box


1 box
50021 type 3 green spot
order code STERIS / BROWNE 7303AB
heat sterilization 160 ºC / 60 min.
100 pcs. / box


1 box
50022 type 4 blue spot
order code STERIS / BROWNE 7304AB
heat sterilization 180 ºC / 12 min.
100 pcs. / box


1 box
50023 type 5 white spot
order code STERIS / BROWNE 7305AB
heat sterilization 160 ºC / 120 min.
and 180 ºC / 35 min.
100 pcs. / box

1 box
* Browne recommends the use of TST ControlTM Cycle Verification (Emulating) Indicators for monitoring porous load steam sterilization processes.